1Troubleshooting & Service for GL/GS Systems50 Hz

Seite 2 - M7 TECHNOLOGY

10230 Volt / 50 Hz Residential Wiring Schematic with 2 Pole RCD Breaker BoxOutside Ground RodONONONONOFFOFFOFFOFFOFFOFFOFFOFFONONONON230VAC House Brea

Seite 3 - Table of Contents

11Spa System BoxTB1HTR2J101 J100HTR1GNJ50T1J1J2J10J57J58J7110VAC10VACJ46J25J26J72J90J28J1AJ2AJ32J52J51F6, T30A 480VAVOZONE PUMP 1OPT. BLWR/PUMP 2CIRC.

Seite 4

12230 Volt / 50 Hz Residential Wiring Schematic with 4 Pole RCD Breaker Box 230 VAC “Live Wire” Neutral +GroundOutside Ground RodONONONONOFFOFFOF

Seite 5 - Service Tools Required

13Spa System BoxTB1HTR2J101 J100HTR1GNJ50T1J1J2J10J57J58J7110VAC10VACJ46J25J26J72J90J28J1AJ2AJ32J52J51F6, T30A 480VAVOZONE PUMP 1OPT. BLWR/PUMP 2CIRC.

Seite 6

14230 Volt 50 Hz - Residual Current Devices (RCD’s)Two Pole RCDFour Pole RCDA residual current device (RCD, or R.C.D. henceforth) is the generic term

Seite 7

15TB1HTR2J101J50J57J25J32J52J51F6, T30A 480VJ471234W1BalboaBALBOA INSTRUMENTS, INC.GS500ZCOPYRIGHT 2007MADE IN U.S.A.P/N 22015_BPb IMPORTANT!Remember,

Seite 8 - Safety Tips

16Diagnosing M7 Topside Control Panels PRELIMINARY PANEL CHECKIf the problem is not obvious, look on the topside control UÊpanel for diagnostic messag

Seite 9 - Wiring Checks

17NOTE: A common programming mistake is overlapping filter times that may cause the spa to filter continuously.Check the water level.UÊCheck the water

Seite 10 - RCD Breaker Box

18SOME TROUBLESHOOTING SCENARIOSYou find out the system is in “OHH”. This alone doesn't explain a lot. What led up to the “OHH” is much more impo

Seite 11 - Spa System Box

19Basic Control System TroubleshootingLOW VOLTAGEAt Balboa, it’s been our experience that the majority of the problems associated with electronic cont

Seite 12

2Balboa’s Patented M7 TechnologyTOPSIDE CONTROL PANELThe control panel activates functions at the touch of a button. Each function will echo from the

Seite 13

20Test the BlowerPlug in the blower.UÊPower up the system and activate the blower.UÊIf the fuse blows, then there is a blower problem.UÊIf the fuse do

Seite 14

21HEATER START UP INFORMATIONOn M-7 systems, the heater goes through a testing phase every time it starts up to assure that there is adequate water flo

Seite 15 - DEDICATED SYSTEM

22ML Series Panels -- For Use with EL and GL Systems “Molex” type ML/GL ConnectorML900ML700ML554ML553ML551ML550ML400ML260ML240ML200JetsLightF2TLF1PLJ

Seite 16 - INSPECT THESE FIRST

23ML900 Panel OperationDiagnostic Messages section for the ML900 is unique. Refer to the User Guide for additional information. User Guide for panel

Seite 17

24Locking the PanelPress “Time” “Jets 1” then “Warm” within 3 seconds. When locked, the PL “PL” light will light. All buttons are frozen except the “T

Seite 18

25ML550, 551, 554 Panel OperationCool/Warm ML500, 551, 554 Press the “Cool” or “Warm” button once to display the set temperature. Each time eithe

Seite 19 - F6, T30A 480V

26ML550, 551, 554 Panel Operation (cont.)Blower 1-speed operation: on/off; 2-speed operation: med/hi/off; or 3-speed operation: lo/med/hi/off. If le

Seite 20 - Important

27Clean-up Cycle (optional) When a pump or blower is turned on by a button press, a clean-up cycle begins 30 minutes after the pump or blower is turne

Seite 21 - PRIMING MODE

28ML550, 551, 554 Panel Operation (cont.) – Dolphin II AddressWhen set to “ ”, no addressing is used. Use this setting for a Dolphin I, or for a Dolph

Seite 22 - Jets Aux Temp Light

29ML200, 240, 260, 400 Panel OperationPlease refer to the following User Guides for more detailed information: ML400 User Guide: P/N 40570-99; ML260 U

Seite 23 - Panel Operation

3Table of ContentsBalboa’s Patented M7 Technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2Balboa

Seite 24

30Pressing “Jets” while in Economy mode puts the spa in Standard-In-Economy mode, (“”) which operates the same as Standard Mode, then reverts to Econo

Seite 25 - ML550, 551, 554

31Ozone (optional) ML400On most systems, the ozone generator (if installed) runs during filter cycles (except when pump 1 is operating at high speed on

Seite 26 - Panel Operation (cont.)

32User Preferences ML400There are several aspects of spa operation that you can customize using the User Preferences submenu.Press “Temp” then “Jets”,

Seite 27

33GL Series Mach 3 -- Persistent Memory & Power UpThis document applies when using ML Series panels with any EL or GL Mach 3 series system.Any tim

Seite 28

34“Phone Plug” RJ Type, VL/GS Connector VL Series Panels -- For use with GS SystemsVL802DVL801DVL702SVL701SVL700SVL600SVL Panel Line-upSTANDARD SYSTEM

Seite 29

35“Phone Plug” RJ Type, VL/GS Connector VL406T VL406UVL404VL402VL401VL400VL260VL240VL200 VL403DUPLEX SYSTEMSJetsLightWarmCoolHeatJetsLightBlower TempH

Seite 30

36TEMP CONTROL (26°C - 40°C / 80°F - 104°F)The last measured water temperature is constantly displayed.The water temperature displayed is current only

Seite 31 - Preset Filter Cycles ML400

37On panels with “Warm” and “Cool” buttons, to display the set temperature, press “Warm” or “Cool” once. To change the set temperature, press a temper

Seite 32

38Preset Filter Cycles 500DZThe first preset filter cycle starts at 8:00 AM and ends UÊat 10:00 AM. The second preset filter cycle starts at 8:00 PM and

Seite 33 - GL, ABOUT PERSISTENT MEMORY

39GS Persistent Memory with VL PanelsAny time you change a DIP Switch, other than A1, you must reset Persistent Memory for your new DIP Switch Setting

Seite 34 - VL Panel Line-up

4230 Volt / 50 Hz Residential Wiring Schematic with 2 Pole RCD Breaker Box . . . . . . . . . . . . . . . . . . . . 10230 Volt / 50 Hz Residential Wir

Seite 35 - DUPLEX SYSTEMS

40Changing a System Circuit Board Important!Be sure to turn the power off before replacing any component, especially a circuit board. Important!DO NOT

Seite 36 - Initial Start-up

41Testing the Sensor SetIf the opposite sensor is now reading higher, UÊthe problem is with the sensor(s). Replace the sensor set.*If you wait more t

Seite 37 - MODE/PROG

42Removing the Heater Assembly from a Spa SystemNote: Be careful when removing a heater assembly from a spa plumbing system. Water may splash out und

Seite 38 - FILTER CYCLES

43Panel Message Reference Guideor5FNQFSBUVSFOPUDVSSFOUJO&DPOPNZPS4MFFQNPEF*O&DPOPNZPS4MFFQNPEFUIFQVNQNBZCFPGGGPSIPVSTPVUT

Seite 39 - SWITCHBANK A

44Panel Message Reference Guide (cont.)5IFQVNQJTPOEVSJOH4UBOECZ.PEFUPBTTJTUJOESBJOJOHUIFTQB1SFTTi+FUTwUPUVSOPGGUIFQVNQXIFOXBU

Seite 40

45i*DFw1PUFOUJBMGSFF[FDPOEJUJPOEFUFDUFE/PBDUJPOSFRVJSFE5IFQVNQTBOEUIFCMPXFSXJMMBVUPNBUJDBMMZBDUJWBUFSFHBSEMFTTPGTQBTUBUVT1FSTJ

Seite 41 - Testing the Sensor Set

46Panel Message Reference Guide (cont.)&WFSZEBZT<> $MFBODPOEJUJPODPWFSQFSNBOVGBDUVSFSTJOTUSVD-UJPOTReminder, Suppress in Us

Seite 42

474QBJTTIVUEPXO<>5IFTFOTPSUIBUJTQMVHHFEJOUPUIF4FOTPSi#wKBDLJTOPUXPSLJOH5FTUTFOTPSBOESFQMBDFJGCBE1MFBTFTFF5FTUJOH

Seite 43 - Panel Message Reference Guide

4840921 Rev A October 31, 2008Tustin, Ca. 92780 (714) 384-0384 ©2008 Balboa Water Group. All rights reserved.

Seite 44

5Balboa Service Tools ChecklistService Tools RequiredAmmeter (50A)UÊBalboa Six-in-one ScrewdriverUÊDigital Multi-meterUÊPadlock (to lock electrical di

Seite 45

6Balboa Service Parts ChecklistRecommended Parts For Service CallsExtra Board(s)UÊExtra Panel(s)UÊFusesUÊJumpersUÊHeater AssemblyUÊ20618 JUMPER LOGICC

Seite 46

7Two Types of Plug-in Connectors:“Molex” Type, ML/GL ConnectorOn Every System, an Identification Label Is Placed on top of the CasingHeater Element

Seite 47

8Troubleshooting & Servicing Spa and Electrical Equipment DANGER Risk of electric shock. Before working with any electrical connections, make

Seite 48

9Wiring Checks WIRING CHECK PRECAUTIONSWhen working in a system box always be aware that it UÊmay contain high voltage.Always keep your fingers and ha

Kommentare zu diesen Handbüchern

Keine Kommentare